Multi-channel power analyser for single or threephase systems installable on panels or DIN rails. Manages current input up to 32 A via a 6-channel current transformer block (TCD06BS with split core or TCD06BX with solid core) connected with RJ-11 connectors.

The EM280 is equipped with a LCD display with controls to display measurements and configure the system, a RS485 port and two pulse outputs or two RS485 ports for daisy chain connections. Thanks to the SUM function, it also displays total load consumption values.

GET A QUOTE

Benefits

Reduced installation time and errors. Equipped with detachable terminals for all connections, with possibility of requesting pre-wired cables (optional). Connected to the 6-channel current transformer block with two cables fitted with RJ-11 connectors. For connections in cascade of multiple EM280s the voltage reference is required once only.

Compact dimensions. It uses a compact current transformer block (TCD06BS or TCD06BX) that performs the function of six transformers, observing the standard dimensions of the switches for DIN rails.

Installation flexibility. It can be installed in new or existing single- and three-phase systems. Suitable for panel or DIN rail mounting .

Granular analysis. It provides total measurements or single load measurements (up to 2 three-phase loads or up to 6 single-phase loads).

Specific software. The UCS proprietary configuration software enables rapid configuration and the display of all measurements. The software and subsequent updates are free.

Tamper-proof. Configuration access can be locked. The terminals and display can be sealed.

Features

• Up to 2 three-phase loads or 6 single-phase loads managed simultaneously.

• Up to 32 A input current via 6-channel transformer block TCD06BS or TCD06BX.

• Three installation configurations: on DIN rails, mounted on panel of 72 x 72 or 96 x 96 (with optional adapter).

• Single load measurements: V, A, W/VA/var, kWh, kvarh. Total load measurements: W/VA/var, kWh, kvarh.

• Display of electrical variables: 3 digits. Display of energy meters: 7 digits.

• Accuracy: better than a combination of a class 1 meter and a class 0.5 current transformer.

• Easy connection function.

• Up to 20 EM280 connected in cascade.

• RS485 port.

• Optional outputs: additional RS485 port for chain connection or two pulse outputs.

• Self power supply via voltage inputs.

• Detachable terminals and sealable terminal caps.

• Configuration via keypad or UCS configuration software.