Size (L×W×H): 199mm × 98mm × 50mm
Product Features:
Availability date:
AC input voltage range |
85-132/170~264VAC selected by switch |
Input frequency |
47-63Hz |
Inrush current |
cold start, 20A/115V, 40A/230V |
Input leakage current |
<0.7mA/230VAC |
Line regulation (full load) |
≤ ±0.5% |
Output Voltage adjust range |
V1: ±5% of rated output voltage |
Output overload protection |
110~130% |
Output over voltage protection |
115~150% |
Withstand voltage |
I/P-O/P : 3.0KVAC/1min |
|
I/P-F/G : 1.5KVAC/1min |
|
O/P-F/G : 0.5KVAC/1min |
Rise time |
50ms@full load (typical) |
Hold up time |
20ms@full load (typical) |
Operating temp. & humidity |
-10°C ~+50°C, 20%~93% RH (non condensing) |
Storage temp. & humidity |
-20°C ~+85°C, 20%~95% RH (non condensing) |
Safety Standards |
meet GB4943, UL60950, EN60950 |
EMC Standards |
meet GB2954, EN55022 class B |
|
EN6100-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11 |
Cooling method |
Convection |
Model |
DC Output |
R&N |
Efficency |
SW-155-12 BAT |
13.8V, 11.5A |
150mV |
80% |
13.3V, 0.5A (Charger) |
|||
SW-155-24 BAT |
27.6V, 2.0A |
150mV |
84% |
27.1V, 0.5A (Charger)
|