<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Single Output Switching Power Supply Archives - SCL System</title>
	<atom:link href="https://www.sclsystem.com.sg/product-category/switchwell/single-output-switching-power-supply/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Best B2B customer experience through a high-touch, high-tech approach</description>
	<lastBuildDate>Mon, 10 Jun 2024 03:24:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.sclsystem.com.sg/wp-content/uploads/2022/04/scl-logo-2-100x100.png</url>
	<title>Single Output Switching Power Supply Archives - SCL System</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SW-15 15 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-15-15-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:18:53 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7987</guid>

					<description><![CDATA[<p>Single Output Switching Power Supply Size (L×W×H): 90mm × 69mm × 37mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage range: [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-15-15-watt-single-output-switching-power-supply/">SW-15 15 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 90mm × 69mm × 37mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC85-265V,  Input connection: 5p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated：AC91mA，Range:  AC75mA～235mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47～63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy：&lt;±2%；±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV ；Vp-p100Hz&lt;120mV；Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">15W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">75%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">120%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input Over voltage protection</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V,  Range AC0~280V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">Natural cooling</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">250g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">5P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-15-5</td>
<td valign="top" width="138">5V, 0~3.0A</td>
</tr>
<tr>
<td valign="top" width="145">SW-15-12</td>
<td valign="top" width="138">12V, 0~1.3A</td>
</tr>
<tr>
<td valign="top" width="145">SW-15-15</td>
<td valign="top" width="138">15V, 0~1.0A</td>
</tr>
<tr>
<td valign="top" width="145">SW-15-24</td>
<td valign="top" width="138">24V, 0~0.7A</p>
<p>&nbsp;</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-15-15-watt-single-output-switching-power-supply/">SW-15 15 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-600 600 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-600-600-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:17:06 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7985</guid>

					<description><![CDATA[<p>600 Watt Single Output Switching Power Supply Size (L×W×H): 320mm × 178mm × 67mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-600-600-watt-single-output-switching-power-supply/">SW-600 600 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>600 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 320mm × 178mm × 67mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 9p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC3A,  Range: AC2.8A~3.6A; AC: 110V:  AC6.2A,  Range: AC5.6A~7.2A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 30A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;12mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">600W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">86%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">By cooling fan *8025</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Dimensions</td>
<td valign="top" nowrap="nowrap" width="368">L320×W178×H67mm³</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight(typical)</td>
<td valign="top" nowrap="nowrap" width="368">1600g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">9P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-600-12</td>
<td valign="top" width="138">12V, 0~50A</td>
</tr>
<tr>
<td valign="top" width="145">SW-600-15</td>
<td valign="top" width="138">15V, 0~40A</td>
</tr>
<tr>
<td valign="top" width="145">SW-600-24</td>
<td valign="top" width="138">24V, 0~25A</td>
</tr>
<tr>
<td valign="top" width="145">SW-600-48</td>
<td valign="top" width="138">48V, 0~12.5A</p>
<p>&nbsp;</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-600-600-watt-single-output-switching-power-supply/">SW-600 600 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-500 500 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-500-500-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:15:32 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7983</guid>

					<description><![CDATA[<p>500 Watt Single Output Switching Power Supply Size (L×W×H): 280mm × 120mm × 50mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-500-500-watt-single-output-switching-power-supply/">SW-500 500 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>500 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 280mm × 120mm × 50mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC3.2A,  Range: AC3.0A~3.8A; AC: 110V:  AC6.4A,  Range: AC6.0A~7.6A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">500W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">86%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">By cooling fan *8025</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Dimensions</td>
<td valign="top" nowrap="nowrap" width="368">L280×W120×H50mm³</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight(typical)</td>
<td valign="top" nowrap="nowrap" width="368">1600g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">9P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-500-12</td>
<td valign="top" width="138">12V, 0~40A</td>
</tr>
<tr>
<td valign="top" width="145">SW-500-15</td>
<td valign="top" width="138">15V, 0~32A</td>
</tr>
<tr>
<td valign="top" width="145">SW-500-24</td>
<td valign="top" width="138">24V, 0~20A</td>
</tr>
<tr>
<td valign="top" width="145">SW-500-48</td>
<td valign="top" width="138">48V, 0~10A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-500-500-watt-single-output-switching-power-supply/">SW-500 500 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-400 400 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-400-400-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:14:04 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7981</guid>

					<description><![CDATA[<p>400 Watt Single Output Switching Power Supply Size (L×W×H): 280mm × 120mm × 50mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-400-400-watt-single-output-switching-power-supply/">SW-400 400 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>400 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 280mm × 120mm × 50mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC2.5A,  Range: AC2.2A~3.0A; AC: 110V:  AC5.0A,  Range: AC4.4A~6.0A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">300W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">86%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">By cooling fan</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Dimensions</td>
<td valign="top" nowrap="nowrap" width="368">L280×W120×H50mm³</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight(typical)</td>
<td valign="top" nowrap="nowrap" width="368">1600g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">7P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-400-5</td>
<td valign="top" width="138">5V, 0~80A</td>
</tr>
<tr>
<td valign="top" width="145">SW-400-12</td>
<td valign="top" width="138">12V, 0~33A</td>
</tr>
<tr>
<td valign="top" width="145">SW-400-15</td>
<td valign="top" width="138">15V, 0~26A</td>
</tr>
<tr>
<td valign="top" width="145">SW-400-24</td>
<td valign="top" width="138">24V, 0~17A</td>
</tr>
<tr>
<td valign="top" width="145">SW-400-48</td>
<td valign="top" width="138">48V, 0~8.5A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-400-400-watt-single-output-switching-power-supply/">SW-400 400 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-ESP-350 350 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-esp-350-350-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:11:08 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7979</guid>

					<description><![CDATA[<p>350 Watt Single Output Switching Power Supply Size (L×W×H): 215mm x 115mm x 50mm Approval: CB Product feature：  &#8211; High reliability &#8211; AC input selectable by switch &#8211; Protections: Overload /Short circuit/Over voltage &#8211; Forced air cooling by built-in DC fan &#8211; 100% full load burn-in test &#8211; One year warranty Specifications: AC input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-esp-350-350-watt-single-output-switching-power-supply/">SW-ESP-350 350 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>350 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 215mm x 115mm x 50mm<br />
Approval: CB</p>
<p><strong>Product feature</strong><strong>：</strong><strong> </strong><br />
&#8211; High reliability<br />
&#8211; AC input selectable by switch<br />
&#8211; Protections: Overload /Short circuit/Over voltage<br />
&#8211; Forced air cooling by built-in DC fan<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" width="577" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" width="577"><strong>Specifications:</strong></td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">AC input voltage</td>
<td valign="bottom" nowrap="nowrap" width="324"> 90~132VAC  180~264VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Input frequency</td>
<td valign="bottom" nowrap="nowrap" width="324"> 50~60Hz</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Input current</td>
<td valign="bottom" nowrap="nowrap" width="324"> 6.5A/4A  at  115VAC/230VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Inrush current</td>
<td valign="bottom" nowrap="nowrap" width="324"> 60A@230VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Hold up time</td>
<td valign="bottom" nowrap="nowrap" width="324">20 ms at 230VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Overload protection</td>
<td valign="bottom" nowrap="nowrap" width="324">105~150% AC restart</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Operating temperature</td>
<td valign="bottom" nowrap="nowrap" width="324"> 0 to 40°C</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Storage temperature</td>
<td valign="bottom" nowrap="nowrap" width="324"> -20°C to 40°C</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Operating humidity</td>
<td valign="bottom" nowrap="nowrap" width="324"> 5% to 90% RH non-condensing</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Storage humidity</td>
<td valign="bottom" nowrap="nowrap" width="324"> 5% to 95% RH non-condensing</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Safety standard</td>
<td valign="bottom" width="324"> EN60950-1 CE Mark</td>
</tr>
<tr>
<td nowrap="nowrap" width="253">EMC standards</td>
<td valign="bottom" width="324"> EN55022 Class B<br />
EN61000-3-2,3<br />
ENV55024<br />
EN61000-4-2,3,4,5,6,8,11</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Withstand voltage</td>
<td valign="bottom" nowrap="nowrap" width="324"> I/P-O/P:3KVAC/1min/5mA</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">&nbsp;</td>
<td valign="bottom" nowrap="nowrap" width="324"> I/P-FG:1.6KVAC/1min/5mA</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">MTBF</td>
<td valign="bottom" nowrap="nowrap" width="324"> 105 Hours per MIL-HDBK-217D</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="253">Weight</td>
<td valign="bottom" nowrap="nowrap" width="324"> 1.1Kg/pcs</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" width="582" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="98">
<p align="center"><strong>P/N</strong></p>
</td>
<td width="88">
<p align="center"><strong>Output</strong></p>
</td>
<td width="56">
<p align="center"><strong>Tol.</strong></p>
</td>
<td width="62">
<p align="center"><strong>R&amp;N</strong></p>
</td>
<td width="54">
<p align="center"><strong>Effi.</strong></p>
</td>
<td width="109">
<p align="center"><strong>Load Regulation</strong></p>
</td>
<td width="115">
<p align="center"><strong>Line Regulation</strong></p>
</td>
</tr>
<tr>
<td width="98">
<p align="center">SW-ESP-350-5</p>
</td>
<td width="88">
<p align="center">5V,0~50A</p>
</td>
<td width="56">
<p align="center">2%</p>
</td>
<td width="62">
<p align="center">150mV</p>
</td>
<td width="54">
<p align="center">74%</p>
</td>
<td width="109">
<p align="center">±1%</p>
</td>
<td width="115">
<p align="center">±2%</p>
</td>
</tr>
<tr>
<td width="98">
<p align="center">SW-ESP-350-12</p>
</td>
<td width="88">
<p align="center">12V,0~29A</p>
</td>
<td width="56">
<p align="center">1%</p>
</td>
<td width="62">
<p align="center">150mV</p>
</td>
<td width="54">
<p align="center">75%</p>
</td>
<td width="109">
<p align="center">±1%</p>
</td>
<td width="115">
<p align="center">±1%</p>
</td>
</tr>
<tr>
<td width="98">
<p align="center">SW-ESP-350-24</p>
</td>
<td width="88">
<p align="center">24V,0~14.6A</p>
</td>
<td width="56">
<p align="center">1%</p>
</td>
<td width="62">
<p align="center">150mV</p>
</td>
<td width="54">
<p align="center">84%</p>
</td>
<td width="109">
<p align="center">±1%</p>
</td>
<td width="115">
<p align="center">±1%</p>
</td>
</tr>
<tr>
<td width="98">
<p align="center">SW-ESP-350-48</p>
</td>
<td width="88">
<p align="center">48V,0~7.3A</p>
</td>
<td width="56">
<p align="center">1%</p>
</td>
<td width="62">
<p align="center">240mV</p>
</td>
<td width="54">
<p align="center">84%</p>
</td>
<td width="109">
<p align="center">±1%</p>
</td>
<td width="115">
<p align="center">±1%</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-esp-350-350-watt-single-output-switching-power-supply/">SW-ESP-350 350 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-300 300 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-300-300-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:09:36 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7977</guid>

					<description><![CDATA[<p>300 Watt Single Output Switching Power Supply Size (L×W×H): 249mm × 98mm × 52mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-300-300-watt-single-output-switching-power-supply/">SW-300 300 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>300 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 249mm × 98mm × 52mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC1.7A,  Range: AC1.4A~2.2A; AC: 110V:  AC3.4A,  Range: AC2.8A~4.8A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">300W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">86%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">By cooling fan</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">1150g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">7P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-300-5</td>
<td valign="top" width="138">5V, 0~60A</td>
</tr>
<tr>
<td valign="top" width="145">SW-300-12</td>
<td valign="top" width="138">12V, 0~25A</td>
</tr>
<tr>
<td valign="top" width="145">SW-300-15</td>
<td valign="top" width="138">15V, 0~20A</td>
</tr>
<tr>
<td valign="top" width="145">SW-300-24</td>
<td valign="top" width="138">24V, 0~12.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-300-48</td>
<td valign="top" width="138">48V, 0~6.5A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-300-300-watt-single-output-switching-power-supply/">SW-300 300 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-240 240 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-240-240-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:08:04 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7975</guid>

					<description><![CDATA[<p>240 Watt Single Output Switching Power Supply Size (L×W×H): 198mm × 98mm × 49mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input voltage [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-240-240-watt-single-output-switching-power-supply/">SW-240 240 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>240 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 198mm × 98mm × 49mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC1.4A,  Range: AC1.2A~2.0A; AC: 110V:  AC2.8A,  Range: AC2.4A~4.0A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">240W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">88%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+40°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">Natural cooling</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">880g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">7P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-240-5</td>
<td valign="top" width="138">5V, 0~40A</td>
</tr>
<tr>
<td valign="top" width="145">SW-240-12</td>
<td valign="top" width="138">12V, 0~16.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-240-15</td>
<td valign="top" width="138">15V, 0~13A</td>
</tr>
<tr>
<td valign="top" width="145">SW-240-24</td>
<td valign="top" width="138">24V, 0~8.3A</td>
</tr>
<tr>
<td valign="top" width="145">SW-240-48</td>
<td valign="top" width="138">48V, 0~4.2A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-240-240-watt-single-output-switching-power-supply/">SW-240 240 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-200 200 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-200-200-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:06:23 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7973</guid>

					<description><![CDATA[<p>200 Watt Single Output Switching Power Supply Size (L×W×H): 198mm × 98mm × 49mm &#160; Product Features: &#160; Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-200-200-watt-single-output-switching-power-supply/">SW-200 200 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>200 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 198mm × 98mm × 49mm</p>
<p>&nbsp;</p>
<p><strong>Product Features:</strong></p>
<p>&nbsp;</p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC1.1A,  Range: AC0.9A~1.4A; AC: 110V:  AC2.2A,  Range: AC1.8A~2.8A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">200W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">86%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">Natural cooling</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">880g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">7P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-200-5</td>
<td valign="top" width="138">5V, 0~40A</td>
</tr>
<tr>
<td valign="top" width="145">SW-200-12</td>
<td valign="top" width="138">12V, 0~16.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-200-15</td>
<td valign="top" width="138">15V, 0~13A</td>
</tr>
<tr>
<td valign="top" width="145">SW-200-24</td>
<td valign="top" width="138">24V, 0~8.3A</td>
</tr>
<tr>
<td valign="top" width="145">SW-200-48</td>
<td valign="top" width="138">48V, 0~4.2A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-200-200-watt-single-output-switching-power-supply/">SW-200 200 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-150 150 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-150-150-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:04:43 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7972</guid>

					<description><![CDATA[<p>150 Watt Single Output Switching Power Supply Size (L×W×H): 198mm × 98mm × 38mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 manufacturer One year warranty Input [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-150-150-watt-single-output-switching-power-supply/">SW-150 150 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>150 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 198mm × 98mm × 38mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC0.85A,  Range: AC0.7A~1.2A; AC: 110V:  AC1.7A,  Range: AC1.4A~2.4A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy: &lt;±2%; ±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV; Vp-p100Hz&lt;120mV; Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">150W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">88%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">Natural cooling</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">780g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">780g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-150-5</td>
<td valign="top" width="138">5V, 0~30A</td>
</tr>
<tr>
<td valign="top" width="145">SW-150-12</td>
<td valign="top" width="138">12V, 0~12.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-150-15</td>
<td valign="top" width="138">15V, 0~10A</td>
</tr>
<tr>
<td valign="top" width="145">SW-150-24</td>
<td valign="top" width="138">24V, 0~6.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-150-48</td>
<td valign="top" width="138">48V, 0~3.2A</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-150-150-watt-single-output-switching-power-supply/">SW-150 150 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-100 100 Watt Single Output Switching Power Supply</title>
		<link>https://www.sclsystem.com.sg/product/sw-100-100-watt-single-output-switching-power-supply/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 07:02:29 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=7966</guid>

					<description><![CDATA[<p>100 Watt Single Output Switching Power Supply Size (L×W×H): 159mm × 98mm × 37mm : 159mm × 98mm × 48mm Product Features: Compact size, light weight; Low price, high reliability International AC input range; built in EMI filter, Low ripple noise Short circuit/over voltage/overload protection High efficiency, low working temp 100% full load burn-in test ISO-9001:2000 [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-100-100-watt-single-output-switching-power-supply/">SW-100 100 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>100 Watt Single Output Switching Power Supply</strong></h3>
<p>Size (L×W×H): 159mm × 98mm × 37mm<br />
: 159mm × 98mm × 48mm</p>
<p><strong>Product Features:</strong></p>
<ul>
<li>Compact size, light weight; Low price, high reliability</li>
<li>International AC input range; built in EMI filter, Low ripple noise</li>
<li>Short circuit/over voltage/overload protection</li>
<li>High efficiency, low working temp</li>
<li>100% full load burn-in test</li>
<li>ISO-9001:2000 manufacturer</li>
<li>One year warranty</li>
</ul>
<table border="1" width="578" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage range:</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC220V/110V,  ±15%,  Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L,  AC-N,  FG</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input current (typical)</td>
<td valign="top" nowrap="nowrap" width="368">Rated: AC: 220V:  AC0.75A,  Range: AC0.6A~1.0A; AC: 110V:  AC1.5A,  Range: AC1.2A~2.0A</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Input voltage frequency</td>
<td valign="top" nowrap="nowrap" width="368">47~63Hz</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Inrush current</td>
<td valign="top" nowrap="nowrap" width="368">Cold start: 20A/10mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output range adjust</td>
<td valign="top" nowrap="nowrap" width="368">Voltage set point accuracy：&lt;±2%；±10% output rated voltage</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Max. Ripple noise</td>
<td valign="top" nowrap="nowrap" width="368">Vnor&lt;24mV ；Vp-p100Hz&lt;120mV；Vp-pmax&lt;240mV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Line / Load regulation</td>
<td valign="top" nowrap="nowrap" width="368">Line:±0.5%; Load:±0.5%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Rated output power</td>
<td valign="top" nowrap="nowrap" width="368">100W</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Efficiency (typical)</td>
<td valign="top" nowrap="nowrap" width="368">85%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over load protection (output)</td>
<td valign="top" nowrap="nowrap" width="368">110%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Over voltage protection…</td>
<td valign="top" nowrap="nowrap" width="368">AC300V±5V</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Under load protection</td>
<td valign="top" nowrap="nowrap" width="368">AC150V±5V; transform to supply as AC Input OK</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Setup,  rise,  hold up time</td>
<td valign="top" nowrap="nowrap" width="368">(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Withstand voltage</td>
<td valign="top" nowrap="nowrap" width="368">[Input-Output: AC1.5KV,  Input-FG: AC1.5KV,  Output-FG: AC0.5KV] 50Hz for 1min: Current limit&lt;5mA</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Temperature coefficient</td>
<td valign="top" nowrap="nowrap" width="368">±0.05 [%/°C]</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Storage temperature</td>
<td valign="top" nowrap="nowrap" width="368">-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Cooling</td>
<td valign="top" nowrap="nowrap" width="368">Natural cooling</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Weight (typical)</td>
<td valign="top" nowrap="nowrap" width="368">450g</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Safety standard</td>
<td valign="top" nowrap="nowrap" width="368">Design refer to UL 1012 &amp; 1950 requirement</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="210">Output connection</td>
<td valign="top" nowrap="nowrap" width="368">7P/10.0-M4 pitch terminal block; OUTPUT: DC+; DC-</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="145"><strong>Model</strong></td>
<td valign="top" width="138"><strong>Output</strong></td>
</tr>
<tr>
<td valign="top" width="145">SW-100-5</td>
<td valign="top" width="138">5V, 0~20A</td>
</tr>
<tr>
<td valign="top" width="145">SW-100-12</td>
<td valign="top" width="138">12V, 0~8.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-100-15</td>
<td valign="top" width="138">15V, 0~6.7A</td>
</tr>
<tr>
<td valign="top" width="145">SW-100-24</td>
<td valign="top" width="138">24V, 0~4.5A</td>
</tr>
<tr>
<td valign="top" width="145">SKJB-120-1BA1 CE</td>
<td valign="top" width="138">24V, 0~4.5A</td>
</tr>
<tr>
<td valign="top" width="145">SW-100-48</td>
<td valign="top" width="138">48V, 0~2.0A</p>
<p>&nbsp;</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-100-100-watt-single-output-switching-power-supply/">SW-100 100 Watt Single Output Switching Power Supply</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
