<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Open-Frame Power Supply Archives - SCL System</title>
	<atom:link href="https://www.sclsystem.com.sg/product-category/switchwell/open-frame-power-supply/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Best B2B customer experience through a high-touch, high-tech approach</description>
	<lastBuildDate>Mon, 10 Jun 2024 03:24:56 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.sclsystem.com.sg/wp-content/uploads/2022/04/scl-logo-2-100x100.png</url>
	<title>Open-Frame Power Supply Archives - SCL System</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SW-OP-60 Open-Frame Power Supply 60 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-60-open-frame-power-supply-60-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:27:47 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8102</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 60 Watt Single Output Size(L×W×H): 195mm×55mm×23mm Product features: &#8211; Universal AC input/ Full range &#8211; Power on indication &#8211; Cooling by free air convection &#8211; Protections: Short circuit /Over voltage/Over load &#8211; 100% full load burn-in test &#8211; One year warranty &#160; Specifications:  AC input voltage:   90~264V AC  Input frequency:   47~63HZ [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-60-open-frame-power-supply-60-watt-single-output/">SW-OP-60 Open-Frame Power Supply 60 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 60 Watt Single Output</strong></h3>
<p>Size(L×W×H): 195mm×55mm×23mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ Full range<br />
&#8211; Power on indication<br />
&#8211; Cooling by free air convection<br />
&#8211; Protections: Short circuit /Over voltage/Over load<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<p>&nbsp;</p>
<table border="1" width="592" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="592"><strong>Specifications:</strong></td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> AC input voltage:</td>
<td width="336">  90~264V AC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input frequency:</td>
<td nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Inrush Current:</td>
<td width="336"> 40A@ 230VAC<br />
25A @ 115VAC<br />
full load cold start</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Set-up time</td>
<td valign="bottom" width="336">  1sec @ 230VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Hold up time</td>
<td valign="bottom" width="336">  20 ms @ fullload,230VAC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Over voltage protection</td>
<td valign="bottom" width="336">  110-135%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Operating Temperature:</td>
<td valign="top" width="336">  0 to 50°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Safety Standards:</td>
<td valign="bottom" nowrap="nowrap" width="336">  IEC60950 IEC60065</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> EMC Standards:</td>
<td valign="bottom" nowrap="nowrap" width="336">  EN55022 (1998) + A1 + A2<br />
EN55013 (2001)+A1<br />
EN55020 (2002) + A1<br />
EN55024(1998)<br />
EN61000-4-2+A1 + A2<br />
EN61000-3-2 EN61000-3-3+A1<br />
EN61000-4-5 EN61000-4-4<br />
EN61000-4-11</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Withstand voltage</td>
<td width="336">  I/P-O/P:3KVAC,1min/6mA</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> MTBF:</td>
<td width="336">  105 h at 25°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Connection:</td>
<td width="336">  3P/6P 3.96mm ; HX39603-3A<br />
HX39603-6A</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Weight:</td>
<td nowrap="nowrap" width="336">  0.3Kg / pcs</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<table border="1" width="597" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="96">
<p align="center"><strong>P/N</strong></p>
</td>
<td valign="top" width="91">
<p align="center"><strong>Output</strong></p>
</td>
<td valign="top" width="55">
<p align="center"><strong>Tol.</strong></p>
</td>
<td valign="top" width="68">
<p align="center"><strong>R&amp;N</strong></p>
</td>
<td valign="top" width="47">
<p align="center"><strong>Effi.</strong></p>
</td>
<td valign="top" width="125">
<p align="center"><strong>Load Regulation</strong></p>
</td>
<td valign="top" width="115">
<p align="center"><strong>Line Regulation</strong></p>
</td>
</tr>
<tr>
<td valign="bottom" width="96">
<p align="center">SW-OP-60-5</p>
</td>
<td valign="bottom" width="91">
<p align="center">5V,0~12A</p>
</td>
<td valign="bottom" width="55">
<p align="center">2%</p>
</td>
<td valign="bottom" width="68">
<p align="center">50mv</p>
</td>
<td valign="bottom" width="47">
<p align="center">76%</p>
</td>
<td valign="bottom" width="125">
<p align="center">2%</p>
</td>
<td valign="bottom" width="115">
<p align="center">±1%</p>
</td>
</tr>
<tr>
<td valign="bottom" width="96">
<p align="center">SW-OP-60-12</p>
</td>
<td valign="bottom" width="91">
<p align="center">12V,0~5A</p>
</td>
<td valign="bottom" width="55">
<p align="center">1%</p>
</td>
<td valign="bottom" width="68">
<p align="center">100mv</p>
</td>
<td valign="bottom" width="47">
<p align="center">80%</p>
</td>
<td valign="bottom" width="125">
<p align="center">1%</p>
</td>
<td valign="bottom" width="115">
<p align="center">±1%</p>
</td>
</tr>
<tr>
<td valign="bottom" width="96">
<p align="center">SW-OP-60-24</p>
</td>
<td valign="bottom" width="91">
<p align="center">24V,0~2.5A</p>
</td>
<td valign="bottom" width="55">
<p align="center">1%</p>
</td>
<td valign="bottom" width="68">
<p align="center">240mV</p>
</td>
<td valign="bottom" width="47">
<p align="center">83%</p>
</td>
<td valign="bottom" width="125">
<p align="center">1%</p>
</td>
<td valign="bottom" width="115">
<p align="center">±1%</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-60-open-frame-power-supply-60-watt-single-output/">SW-OP-60 Open-Frame Power Supply 60 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-150 Open-Frame Power Supply 150 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-150-open-frame-power-supply-150-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:26:30 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8100</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 150 Watt Single Output Size(L×W×H): 116mm×108mm×50mm Product features: &#8211; Universal AC input/ full range &#8211; PF&#62;0.99@115VAC &#8211; High efficiency, high reliability &#8211; Power on indication &#8211; Protections: Overload /Over voltage /Short Circuit &#8211; 100% full load burn-in test &#8211; One year warranty &#160; Specifications AC input voltage 90~264VAC Nominal 100~240VAC Input frequency 47~63Hz [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-150-open-frame-power-supply-150-watt-single-output/">SW-OP-150 Open-Frame Power Supply 150 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 150 Watt Single Output</strong></h3>
<p>Size(L×W×H): 116mm×108mm×50mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ full range<br />
&#8211; PF&gt;0.99@115VAC<br />
&#8211; High efficiency, high reliability<br />
&#8211; Power on indication<br />
&#8211; Protections: Overload /Over voltage /Short Circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="590"><strong>Specifications</strong></td>
</tr>
<tr>
<td valign="top" width="238">AC input voltage</td>
<td valign="top" width="353">90~264VAC<br />
Nominal 100~240VAC</td>
</tr>
<tr>
<td valign="top" width="238">Input frequency</td>
<td valign="top" width="353">47~63Hz</td>
</tr>
<tr>
<td valign="top" width="238">Inrush current</td>
<td valign="top" width="353">50A@230VAC<br />
40A@110VAC<br />
full load, cold start</td>
</tr>
<tr>
<td valign="top" width="238">DC output voltage</td>
<td valign="bottom" width="353">24V,48V</td>
</tr>
<tr>
<td valign="top" width="238">Over voltage protection</td>
<td valign="bottom" width="353">115%~135 %</td>
</tr>
<tr>
<td valign="top" width="238">hold up time</td>
<td valign="bottom" width="353">20ms@120VAC</td>
</tr>
<tr>
<td valign="bottom" width="238">Operating temperature</td>
<td valign="bottom" width="353">-10 to 40°C</td>
</tr>
<tr>
<td valign="bottom" width="238">Storage temperature</td>
<td valign="bottom" width="353">-20 to 85°C</td>
</tr>
<tr>
<td valign="bottom" width="238">Operating humidity</td>
<td valign="bottom" width="353">20%~90%<br />
RH, non-condensing</td>
</tr>
<tr>
<td valign="bottom" width="238">Storage humidity</td>
<td valign="top" width="353">5%~90%<br />
RH, non-condensing</td>
</tr>
<tr>
<td valign="bottom" width="238">Safety standards</td>
<td valign="top" width="353">UL1950<br />
EN60950<br />
CSA22.2 NO CE Mark</td>
</tr>
<tr>
<td valign="bottom" width="238">EMI standard</td>
<td valign="top" width="353">EN55022 class B</td>
</tr>
<tr>
<td valign="bottom" width="238">EMC standards</td>
<td valign="top" width="353">EN61000-4-2,3,4,5,6<br />
EN61000-4-8,9,11</td>
</tr>
<tr>
<td valign="top" width="238">MTBF</td>
<td valign="top" width="353">105 h at 25°C</td>
</tr>
<tr>
<td valign="top" width="238">Weight</td>
<td valign="top" width="353">1Kg/pcs</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-150-open-frame-power-supply-150-watt-single-output/">SW-OP-150 Open-Frame Power Supply 150 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-100 Open-Frame Power Supply 100 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-100-open-frame-power-supply-100-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:24:59 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8098</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 100 Watt Single Output Size(L×W×H): 222mm×62mm×32mm Product features: &#8211; AC input range selectable by switch &#8211; Protections: Over voltage /Short Circuit &#8211; 100% full load burn-in test &#8211; One year warranty Specifications AC input voltage 88~132VAC 176~264VAC Nominal 100~240Vac Input frequency 47~63Hz Inrush current 40A @230VAC full load cold start 20A @115VAC full [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-100-open-frame-power-supply-100-watt-single-output/">SW-OP-100 Open-Frame Power Supply 100 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 100 Watt Single Output</strong></h3>
<p>Size(L×W×H): 222mm×62mm×32mm</p>
<p>Product features:<br />
&#8211; AC input range selectable by switch<br />
&#8211; Protections: Over voltage /Short Circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="top" width="619"><strong>Specifications</strong></td>
</tr>
<tr>
<td valign="top" width="250">AC input voltage</td>
<td valign="top" width="370">88~132VAC<br />
176~264VAC<br />
Nominal 100~240Vac</td>
</tr>
<tr>
<td valign="top" width="250">Input frequency</td>
<td valign="top" width="370">47~63Hz</td>
</tr>
<tr>
<td valign="top" width="250">Inrush current</td>
<td valign="top" width="370">40A @230VAC full load cold start<br />
20A @115VAC full load cold start</td>
</tr>
<tr>
<td valign="top" width="250">hold up time</td>
<td valign="top" width="370">20ms</td>
</tr>
<tr>
<td valign="top" width="250">Over voltage protection</td>
<td valign="top" width="370">110-160%</td>
</tr>
<tr>
<td valign="top" width="250">Working temperature</td>
<td valign="top" width="370">0 to 40°C</td>
</tr>
<tr>
<td valign="top" width="250">Safety standard</td>
<td valign="top" width="370">UL60950-1</td>
</tr>
<tr>
<td valign="top" width="250">EMC standard</td>
<td valign="top" width="370">EN55022 class B</td>
</tr>
<tr>
<td valign="top" width="250">MTBF</td>
<td valign="top" width="370">105 h at 25°C</td>
</tr>
<tr>
<td valign="top" width="250">Withstand Voltage</td>
<td valign="top" width="370">I/P-O/P:3KV, 1min/10mA<br />
I/P-FG:1.5KV,1min/10mA</td>
</tr>
<tr>
<td valign="top" width="250">Weight</td>
<td valign="top" width="370">0.5Kg/pcs</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" width="604" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="103">
<p align="center"><strong>P/N</strong></p>
</td>
<td valign="top" width="91">
<p align="center"><strong>Output</strong></p>
</td>
<td valign="top" width="55">
<p align="center"><strong>Tol.</strong></p>
</td>
<td valign="top" width="68">
<p align="center"><strong>R&amp;N</strong></p>
</td>
<td valign="top" width="47">
<p align="center"><strong>Effi.</strong></p>
</td>
<td valign="top" width="125">
<p align="center"><strong>Load Regulation</strong></p>
</td>
<td valign="top" width="115">
<p align="center"><strong>Line Regulation</strong></p>
</td>
</tr>
<tr>
<td valign="top" width="103">
<p align="center">SW-OP-100-5</p>
</td>
<td valign="top" width="91">
<p align="center">5V,20A</p>
</td>
<td valign="top" width="55">
<p align="center">3%</p>
</td>
<td valign="top" width="68">
<p align="center">100mV</p>
</td>
<td valign="top" width="47">
<p align="center">77%</p>
</td>
<td valign="top" width="125">
<p align="center">2%</p>
</td>
<td valign="top" width="115">
<p align="center">2%</p>
</td>
</tr>
<tr>
<td valign="top" width="103">
<p align="center">SW-OP-100-12</p>
</td>
<td valign="top" width="91">
<p align="center">12V,8.4A</p>
</td>
<td valign="top" width="55">
<p align="center">2%</p>
</td>
<td valign="top" width="68">
<p align="center">100mV</p>
</td>
<td valign="top" width="47">
<p align="center">79%</p>
</td>
<td valign="top" width="125">
<p align="center">1%</p>
</td>
<td valign="top" width="115">
<p align="center">1%</p>
</td>
</tr>
<tr>
<td valign="top" width="103">
<p align="center">SW-OP-100-24</p>
</td>
<td valign="top" width="91">
<p align="center">24V,2.1A</p>
</td>
<td valign="top" width="55">
<p align="center">1%</p>
</td>
<td valign="top" width="68">
<p align="center">150mV</p>
</td>
<td valign="top" width="47">
<p align="center">80%</p>
</td>
<td valign="top" width="125">
<p align="center">1%</p>
</td>
<td valign="top" width="115">
<p align="center">1%</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-100-open-frame-power-supply-100-watt-single-output/">SW-OP-100 Open-Frame Power Supply 100 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-50 Open-Frame Power Supply 50 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-50-open-frame-power-supply-50-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:23:26 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8096</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 50 Watt Single Output Size(L×W×H): 195mm×55mm×23mm Product features: &#8211; Universal AC input/ full range &#8211; Protections: Overload / Short circuit &#8211; 100% full load burn-in test &#8211; One year warranty Specifications:  AC input voltage:   90~264V AC Nominal 100~240VAC  Input frequency:   47~63HZ  Inrush Current:   35A@ 230VAC 18A @ 115VAC full load [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-50-open-frame-power-supply-50-watt-single-output/">SW-OP-50 Open-Frame Power Supply 50 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 50 Watt Single Output</strong></h3>
<p>Size(L×W×H): 195mm×55mm×23mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ full range<br />
&#8211; Protections: Overload / Short circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" width="592" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="592"><strong>Specifications:</strong></td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> AC input voltage:</td>
<td width="336">  90~264V AC<br />
Nominal 100~240VAC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input frequency:</td>
<td nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Inrush Current:</td>
<td width="336">  35A@ 230VAC<br />
18A @ 115VAC<br />
full load cold start</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Hold up time</td>
<td valign="bottom" width="336">  20 ms</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Over voltage protection</td>
<td valign="bottom" width="336">  110-160%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Operating Temperature:</td>
<td valign="top" width="336">  0 to 40°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Safety Standards:</td>
<td valign="bottom" nowrap="nowrap" width="336">  UL60950-1</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> EMC Standards:</td>
<td valign="bottom" nowrap="nowrap" width="336">  EN55022 class B</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Withstand voltage</td>
<td width="336">  I/P-O/P: 3KVAC,1min/10mA<br />
I/P-FG:1.5KVAC,1min/10mA</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> MTBF:</td>
<td width="336">  105 h at 25°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Weight:</td>
<td nowrap="nowrap" width="336">  0.24Kg / pcs</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<table border="1" width="609" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="108">
<p align="center"><strong>P/N</strong></p>
</td>
<td valign="top" width="91">
<p align="center"><strong>Output</strong></p>
</td>
<td valign="top" width="55">
<p align="center"><strong>Tol.</strong></p>
</td>
<td valign="top" width="68">
<p align="center"><strong>R&amp;N</strong></p>
</td>
<td valign="top" width="47">
<p align="center"><strong>Effi.</strong></p>
</td>
<td valign="top" width="125">
<p align="center"><strong>Load Regulation</strong></p>
</td>
<td valign="top" width="115">
<p align="center"><strong>Line Regulation</strong></p>
</td>
</tr>
<tr>
<td valign="bottom" width="108">
<p align="center">SW-OP-50-5</p>
</td>
<td valign="bottom" width="91">
<p align="center">5V,10A</p>
</td>
<td valign="bottom" width="55">
<p align="center">2%</p>
</td>
<td valign="bottom" width="68">
<p align="center">80mV</p>
</td>
<td valign="bottom" width="47">
<p align="center">81%</p>
</td>
<td valign="bottom" width="125">
<p align="center">2%</p>
</td>
<td valign="bottom" width="115">
<p align="center">2%</p>
</td>
</tr>
<tr>
<td valign="bottom" width="108">
<p align="center">SW-OP-50-12</p>
</td>
<td valign="bottom" width="91">
<p align="center">12V,4.2A</p>
</td>
<td valign="bottom" width="55">
<p align="center">1%</p>
</td>
<td valign="bottom" width="68">
<p align="center">100mV</p>
</td>
<td valign="bottom" width="47">
<p align="center">82%</p>
</td>
<td valign="bottom" width="125">
<p align="center">1%</p>
</td>
<td valign="bottom" width="115">
<p align="center">1%</p>
</td>
</tr>
<tr>
<td valign="bottom" width="108">
<p align="center">SW-OP-50-24</p>
</td>
<td valign="bottom" width="91">
<p align="center">24V,2.1A</p>
</td>
<td valign="bottom" width="55">
<p align="center">1%</p>
</td>
<td valign="bottom" width="68">
<p align="center">200mV</p>
</td>
<td valign="bottom" width="47">
<p align="center">85%</p>
</td>
<td valign="bottom" width="125">
<p align="center">1%</p>
</td>
<td valign="bottom" width="115">
<p align="center">1%</p>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-50-open-frame-power-supply-50-watt-single-output/">SW-OP-50 Open-Frame Power Supply 50 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-30 Open-Frame Power Supply 30 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-30-open-frame-power-supply-30-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:21:44 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8093</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 30 Watt Single Output Size(L×W×H): 100mm×50mm×30mm Product features: &#8211; Universal AC input/ full range &#8211; Work temperature -40 ~85 °C &#8211; Protections: Overload /Over voltage / Over temperature/Short circuit &#8211; 100% full load burn-in test &#8211; One year warranty Specifications:  AC input voltage:   90~264V AC  Output voltage   24V  Input frequency:   [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-30-open-frame-power-supply-30-watt-single-output/">SW-OP-30 Open-Frame Power Supply 30 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 30 Watt Single Output</strong></h3>
<p>Size(L×W×H): 100mm×50mm×30mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ full range<br />
&#8211; Work temperature -40 ~85 °C<br />
&#8211; Protections: Overload /Over voltage / Over temperature/Short circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" width="592" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="592"><strong>Specifications:</strong></td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> AC input voltage:</td>
<td width="336">  90~264V AC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Output voltage</td>
<td nowrap="nowrap" width="336">  24V</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input frequency:</td>
<td nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Operating Temperature:</td>
<td valign="top" width="336">  -40 ~85 °C</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Storage Temperature:</td>
<td valign="top" width="336">  -40 to 90 °C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Relative humidity:</td>
<td nowrap="nowrap" width="336">  5% to 95%</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Load</td>
<td valign="bottom" nowrap="nowrap" width="336">  0~1.25A</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> R&amp;N</td>
<td valign="bottom" nowrap="nowrap" width="336">  ≤240mV</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Efficiency</td>
<td valign="bottom" nowrap="nowrap" width="336">  ＞82%</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Safety Standards:</td>
<td nowrap="nowrap" width="336">  IEC60950<br />
IEC60065<br />
UL60950<br />
GB4943-2001</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> EMC Standards:</td>
<td nowrap="nowrap" width="336">  EN55022<br />
EN55013 EN55020<br />
EN55024<br />
EN61000-3-2<br />
EN61000-3-3＋A1<br />
EN61000-4-5<br />
EN61000-4-11<br />
EN61000-4-4<br />
EN61000-4-2</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> MTBF:</td>
<td width="336">  105 h at 25°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Weight:</td>
<td nowrap="nowrap" width="336">  0.11Kg / pcs</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-30-open-frame-power-supply-30-watt-single-output/">SW-OP-30 Open-Frame Power Supply 30 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-24L Open-Frame Power Supply 24 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-24l-open-frame-power-supply-24-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:20:28 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8091</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 24 Watt Single Output Size(L×W×H): 60mm×60mm×30mm Product features: &#8211; Universal AC input/ full range &#8211; Cooling by air convection &#8211; Protections: Overload /Over voltage / Over temperature/Short circuit &#8211; 100% full load burn-in test &#8211; One year warranty Specifications:  AC input voltage:   90~264V AC  Input frequency:   47~63HZ  Inrush Current:   40A@230 [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-24l-open-frame-power-supply-24-watt-single-output/">SW-OP-24L Open-Frame Power Supply 24 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="product-description">
<h3><strong>Open-Frame Power Supply 24 Watt Single Output</strong></h3>
<p>Size(L×W×H): 60mm×60mm×30mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ full range<br />
&#8211; Cooling by air convection<br />
&#8211; Protections: Overload /Over voltage / Over temperature/Short circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" width="592" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="592"><strong>Specifications:</strong></td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> AC input voltage:</td>
<td valign="bottom" width="336">  90~264V AC</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Input frequency:</td>
<td valign="bottom" nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Inrush Current:</td>
<td valign="bottom" width="336">  40A@230</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Overload protection</td>
<td valign="bottom" width="336">  105%~180%</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Operating Temperature:</td>
<td valign="bottom" width="336">  -5 to 40°C</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Storage Temperature:</td>
<td valign="bottom" width="336">  -40 to 85°C</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Operating humidity:</td>
<td valign="bottom" nowrap="nowrap" width="336">  5% to 95% RH, non-condensing</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Storage humidity:</td>
<td valign="bottom" nowrap="nowrap" width="336">  5% to 95% RH, non-condensing</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Safety &amp; EMC Standards:</td>
<td valign="bottom" nowrap="nowrap" width="336">  EN55022 class B<br />
UL60950<br />
EN60950<br />
BG4943-2001</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Withstand voltage</td>
<td valign="bottom" width="336">  I/P-O/P:3KV,1min<br />
I/P-FG:0.5KV,1min</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> MTBF:</td>
<td valign="bottom" width="336">  105 h at 25°C</td>
</tr>
<tr>
<td valign="bottom" nowrap="nowrap" width="256"> Weight:</td>
<td valign="bottom" nowrap="nowrap" width="336">  0.04Kg / pcs</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="108">
<p align="center"><strong>P/N</strong></p>
</td>
<td valign="top" width="91">
<p align="center"><strong>Output</strong></p>
</td>
<td valign="top" width="55">
<p align="center"><strong>Tol.</strong></p>
</td>
<td valign="top" width="68">
<p align="center"><strong>R&amp;N</strong></p>
</td>
<td valign="top" width="47">
<p align="center"><strong>Effi.</strong></p>
</td>
<td valign="top" width="125">
<p align="center"><strong>Line Regulation</strong></p>
</td>
</tr>
<tr>
<td width="108">
<p align="center">SW-OP-24-12</p>
</td>
<td width="91">
<p align="center">12V,0~2A</p>
</td>
<td width="55">
<p align="center">3%</p>
</td>
<td width="68">
<p align="center">240mV</p>
</td>
<td width="47">
<p align="center">75%</p>
</td>
<td width="125">
<p align="center">2%</p>
</td>
</tr>
<tr>
<td valign="top" width="108">
<p align="center">SW-OP-24-48</p>
</td>
<td valign="top" width="91">
<p align="center">48V,0~0.5A</p>
</td>
<td valign="top" width="55">
<p align="center">3%</p>
</td>
<td valign="top" width="68">
<p align="center">120mV</p>
</td>
<td valign="top" width="47">
<p align="center">75%</p>
</td>
<td valign="top" width="125">
<p align="center">2%</p>
</td>
</tr>
</tbody>
</table>
</div>
<div id="oosHook"></div>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-24l-open-frame-power-supply-24-watt-single-output/">SW-OP-24L Open-Frame Power Supply 24 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-12 Open-Frame Power Supply 12 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-12-open-frame-power-supply-12-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:19:12 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8089</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 12 Watt Single Output Size(L×W×H): 71mm x 44.5mm x 29mm Product features: &#8211; 150HW low power stay up &#8211; Over current / over voltage protection adjustable &#8211; Protections: Over temperature/short circuit / short voltage protection &#8211; Universal AC input/full range &#8211; Cold Start &#8211; One year warranty &#160; Specifications:  AC input voltage:   [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-12-open-frame-power-supply-12-watt-single-output/">SW-OP-12 Open-Frame Power Supply 12 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 12 Watt Single Output</strong></h3>
<p>Size(L×W×H): 71mm x 44.5mm x 29mm</p>
<p><strong>Product features:</strong><br />
&#8211; 150HW low power stay up<br />
&#8211; Over current / over voltage protection adjustable<br />
&#8211; Protections: Over temperature/short circuit / short voltage protection<br />
&#8211; Universal AC input/full range<br />
&#8211; Cold Start<br />
&#8211; One year warranty</p>
<p>&nbsp;</p>
<table border="1" width="538" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="536"><strong>Specifications:</strong></td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> AC input voltage:</td>
<td width="304">  90~264V AC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input frequency:</td>
<td nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input current:</td>
<td nowrap="nowrap" width="336">  0.25~0.4A at 110~220VAC</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Inrush Current:</td>
<td width="304">  50A @ 220VAC<br />
30A @ 110VAC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Leakage Current:</td>
<td nowrap="nowrap" width="336">  2mA</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Hold-up Time:</td>
<td nowrap="nowrap" width="336">  20mS typ</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Safety Standards:</td>
<td width="304">  UL1950<br />
CSA 22.2 No.234<br />
EN60950/TUV</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> EMI Standards:</td>
<td width="304">  FCC Part 15 CLASS &#8216;B&#8217;<br />
EN55022 class B</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Operating Temperature:</td>
<td nowrap="nowrap" width="336">  0~40°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Storage Temperature:</td>
<td nowrap="nowrap" width="336">  -40~70°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Operating humidity:</td>
<td nowrap="nowrap" width="336">  5% to 90% RH, non-condensing</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Storage humidity:</td>
<td nowrap="nowrap" width="336">  5% to 90% RH, non-condensing</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Ripple and noise:</td>
<td nowrap="nowrap" width="336">  150mV</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Line regulation:</td>
<td nowrap="nowrap" width="336">  ±1%</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Load regulation:</td>
<td nowrap="nowrap" width="336">  ±2%</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Efficiency:</td>
<td nowrap="nowrap" width="336">  ≥75%</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> MTBF:</td>
<td width="304"> 105 h at 25°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Weight:</td>
<td nowrap="nowrap" width="336">  0.05Kg/pcs</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-12-open-frame-power-supply-12-watt-single-output/">SW-OP-12 Open-Frame Power Supply 12 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SW-OP-6 Open-Frame Power Supply 6 Watt Single Output</title>
		<link>https://www.sclsystem.com.sg/product/sw-op-6-open-frame-power-supply-6-watt-single-output/</link>
		
		<dc:creator><![CDATA[Shop Manager]]></dc:creator>
		<pubDate>Tue, 30 Apr 2024 08:18:01 +0000</pubDate>
				<guid isPermaLink="false">https://sclsystem.creaworld.sg/?post_type=product&#038;p=8087</guid>

					<description><![CDATA[<p>Open-Frame Power Supply 6 Watt Single Output Size(L×W×H): 50mm×50mm×30mm Product features: &#8211; Universal AC input/ full range &#8211; Cooling by air convection &#8211; Protections: Overload /Over voltage / Over temperature/Short circuit &#8211; 100% full load burn-in test &#8211; One year warranty Specifications:  AC input voltage:   90~264V AC  Input frequency:   47~63HZ  Inrush Current:   30A@230 VAC [&#8230;]</p>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-6-open-frame-power-supply-6-watt-single-output/">SW-OP-6 Open-Frame Power Supply 6 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3><strong>Open-Frame Power Supply 6 Watt Single Output</strong></h3>
<p>Size(L×W×H): 50mm×50mm×30mm</p>
<p><strong>Product features:</strong><br />
&#8211; Universal AC input/ full range<br />
&#8211; Cooling by air convection<br />
&#8211; Protections: Overload /Over voltage / Over temperature/Short circuit<br />
&#8211; 100% full load burn-in test<br />
&#8211; One year warranty</p>
<table border="1" width="592" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" valign="bottom" nowrap="nowrap" width="592"><strong>Specifications:</strong></td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> AC input voltage:</td>
<td width="336">  90~264V AC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Input frequency:</td>
<td nowrap="nowrap" width="336">  47~63HZ</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Inrush Current:</td>
<td width="336">  30A@230 VAC</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Hold-up Time:</td>
<td nowrap="nowrap" width="336"> 20ms@230VAC</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Overload protection</td>
<td valign="top" width="336">  105%~180%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Operating Temperature:</td>
<td valign="top" width="336">  -5 to 40°C</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Storage Temperature:</td>
<td valign="top" width="336">  -20 to 65°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Operating humidity:</td>
<td nowrap="nowrap" width="336">  0% to 90% RH, non-condensing</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Storage humidity:</td>
<td nowrap="nowrap" width="336">  0% to 90% RH, non-condensing</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> R&amp;N:</td>
<td nowrap="nowrap" width="336">  120mV</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Efficiency:</td>
<td nowrap="nowrap" width="336">  ≥78%</td>
</tr>
<tr>
<td valign="top" nowrap="nowrap" width="256"> Safety &amp; EMC Standards:</td>
<td nowrap="nowrap" width="336">  EN55022<br />
IEC60950<br />
IEC60065</td>
</tr>
<tr>
<td nowrap="nowrap" width="256">Withstand voltage</td>
<td width="336">  I/P-O/P:3KV,1min</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> MTBF:</td>
<td width="336">  105 h at 25°C</td>
</tr>
<tr>
<td nowrap="nowrap" width="256"> Weight:</td>
<td nowrap="nowrap" width="336">  0.04Kg / pcs</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.sclsystem.com.sg/product/sw-op-6-open-frame-power-supply-6-watt-single-output/">SW-OP-6 Open-Frame Power Supply 6 Watt Single Output</a> appeared first on <a href="https://www.sclsystem.com.sg">SCL System</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
