Size (L×W×H): 198mm × 98mm × 38mm
Product Features:
Availability date:
Input voltage range: |
Rated: AC220V/110V, ±15%, Input connection: 7p/10.0-M4 pitch terminal INPUT: AC-L, AC-N, FG |
Input current (typical) |
Rated: AC: 220V: AC0.85A, Range: AC0.7A~1.2A; AC: 110V: AC1.7A, Range: AC1.4A~2.4A |
Input voltage frequency |
47~63Hz |
Inrush current |
Cold start: 20A/10mS |
Output range adjust |
Voltage set point accuracy: <±2%; ±10% output rated voltage |
Max. Ripple noise |
Vnor<24mV; Vp-p100Hz<120mV; Vp-pmax<240mV |
Line / Load regulation |
Line:±0.5%; Load:±0.5% |
Rated output power |
150W |
Efficiency (typical) |
88% |
Over load protection (output) |
110% |
Over voltage protection… |
AC300V±5V |
Under load protection |
AC150V±5V; transform to supply as AC Input OK |
Setup, rise, hold up time |
(SETUP TIME)≈200mS; (RISE TIME) ~50mS; (HOLD UP TIME) ~ 20mS |
Withstand voltage |
[Input-Output: AC1.5KV, Input-FG: AC1.5KV, Output-FG: AC0.5KV] 50Hz for 1min: Current limit<5mA |
Temperature coefficient |
±0.05 [%/°C] |
Storage temperature |
-20°C ~ +85°C; 10% ~ 95%RH. Working Temp.: -10°C~+50°C; 20%~90%RH |
Cooling |
Natural cooling |
Weight (typical) |
780g |
Safety standard |
780g |
Safety standard |
Design refer to UL 1012 & 1950 requirement |
Model |
Output |
SW-150-5 |
5V, 0~30A |
SW-150-12 |
12V, 0~12.5A |
SW-150-15 |
15V, 0~10A |
SW-150-24 |
24V, 0~6.5A |
SW-150-48 |
48V, 0~3.2A |